> >menu 1 ) Analysis Interval = 60 min. 2 ) System Startup Delay = 1 min. 3 ) Demand Ratio Ideal = 70 % 4 ) Actual Demand Ratio Min = 10 % 5 ) Startup Temperature = 150 deg. 6 ) Deg Change Increment = 3 deg. 7 ) Range Differential = 10 deg. 8 ) High Temp Absolute = 200 deg. 9 ) High Temp Safety = 250 deg. 10 ) Low Temp Absolute = 150 deg. 11 ) Low Temp Safety = 50 deg. 12 ) Temperature Averaging = 5 sec. 13 ) Thermostat Polarity = 1 deg. 14 ) HotWaterLowTemp = 0 deg. >? ExqHeat Controller PSoC Sep 20 2006 TEMP 11/28/07 08:15.28 PM Current source temp = 164 deg. Low temp limit = 140 deg. High temp limit = 150 deg. Desired Demand Ratio = 70 % Actual Demand Ratio = 0 % Thermostat = Off. Source = Off. >menu 1 ) Analysis Interval = 60 min. 2 ) System Startup Delay = 1 min. 3 ) Demand Ratio Ideal = 70 % 4 ) Actual Demand Ratio Min = 10 % 5 ) Startup Temperature = 150 deg. 6 ) Deg Change Increment = 3 deg. 7 ) Range Differential = 10 deg. 8 ) High Temp Absolute = 200 deg. 9 ) High Temp Safety = 250 deg. 10 ) Low Temp Absolute = 150 deg. 11 ) Low Temp Safety = 50 deg. 12 ) Temperature Averaging = 5 sec. 13 ) Thermostat Polarity = 1 deg. 14 ) HotWaterLowTemp = 0 deg. >rtm 0 days remaining. >11/28/07 08:16.03 PM Setting System Online for Startup. Temp = 160 deg. menu 1 ) Analysis Interval = 60 min. 2 ) System Startup Delay = 1 min. 3 ) Demand Ratio Ideal = 80 % 4 ) Actual Demand Ratio Min = 10 % 5 ) Startup Temperature = 155 deg. 6 ) Deg Change Increment = 2 deg. 7 ) Range Differential = 10 deg. 8 ) High Temp Absolute = 180 deg. 9 ) High Temp Safety = 250 deg. 10 ) Low Temp Absolute = 145 deg. 11 ) Low Temp Safety = 50 deg. 12 ) Temperature Averaging = 5 sec. 13 ) Thermostat Polarity = 0 deg. 14 ) HotWaterLowTemp = 0 deg. >temp Temp = 148 deg. >edit 10 The current Low Temp Absolute = 145 deg. Enter the new Low Temp Absolute : > 135 > OK. Setting Low Temp Absolute = 135 deg. >Saving Settings...Done. menu 1 ) Analysis Interval = 60 min. 2 ) System Startup Delay = 1 min. 3 ) Demand Ratio Ideal = 80 % 4 ) Actual Demand Ratio Min = 10 % 5 ) Startup Temperature = 155 deg. 6 ) Deg Change Increment = 2 deg. 7 ) Range Differential = 10 deg. 8 ) High Temp Absolute = 180 deg. 9 ) High Temp Safety = 250 deg. 10 ) Low Temp Absolute = 135 deg. 11 ) Low Temp Safety = 50 deg. 12 ) Temperature Averaging = 5 sec. 13 ) Thermostat Polarity = 0 deg. 14 ) HotWaterLowTemp = 0 deg. >rtm 0 days remaining. >? ExqHeat Controller PSoC Sep 20 2006 TEMP 12/07/07 08:47.47 PM Current source temp = 148 deg. Low temp limit = 145 deg. High temp limit = 155 deg. Desired Demand Ratio = 80 % Actual Demand Ratio = 75 % Thermostat = On . Source = Off. >temp Temp = 143 deg. >12/07/07 09:05.25 PM Source Off Temp = 155 deg. 12/07/07 09:19.51 PM Source On Temp = 144 deg. ( 4 ) 12/07/07 09:25.53 PM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 3600 of 3600 = 100 % Source Ratio = 1748 of 3600 = 48 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 100 % Temp Change Factor = 20 Deg Change Increment = 2 Old Temp Set Point = 155 deg. New Temp Set Point = 159 deg. 12/07/07 09:59.39 PM Source Off Temp = 159 deg. 12/07/07 10:15.29 PM Source On Temp = 148 deg. 12/07/07 10:21.46 PM Thermostat Off Temp = 149 deg. ( 5 ) 12/07/07 10:24.51 PM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 3411 of 3600 = 94 % Source Ratio = 2638 of 3600 = 73 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 94 % Temp Change Factor = 14 Deg Change Increment = 2 Old Temp Set Point = 159 deg. New Temp Set Point = 162 deg. 12/07/07 10:30.16 PM Source Off Temp = 162 deg. 12/07/07 10:44.18 PM Source On Temp = 151 deg. 12/07/07 10:46.21 PM Thermostat On Temp = 150 deg. 12/07/07 10:58.15 PM Source Off Temp = 162 deg. 12/07/07 11:07.55 PM Source On Temp = 151 deg. 12/07/07 11:21.28 PM Source Off Temp = 162 deg. ( 6 ) 12/07/07 11:24.02 PM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 2295 of 3600 = 63 % Source Ratio = 2005 of 3600 = 55 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 63 % Temp Change Factor = - 17 Deg Change Increment = 2 Old Temp Set Point = 162 deg. New Temp Set Point = 159 deg. 12/07/07 11:37.00 PM Source On Temp = 148 deg. 12/07/07 11:49.30 PM Source Off Temp = 159 deg. 12/08/07 12:04.38 AM Source On Temp = 148 deg. 12/08/07 12:18.36 AM Source Off Temp = 159 deg. ( 7 ) 12/08/07 12:23.15 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 3600 of 3600 = 100 % Source Ratio = 1612 of 3600 = 44 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 100 % Temp Change Factor = 20 Deg Change Increment = 2 Old Temp Set Point = 159 deg. New Temp Set Point = 163 deg. 12/08/07 12:29.50 AM Source On Temp = 152 deg. 12/08/07 12:43.16 AM Source Off Temp = 163 deg. 12/08/07 12:53.45 AM Source On Temp = 152 deg. 12/08/07 01:06.07 AM Thermostat Off Temp = 161 deg. 12/08/07 01:06.54 AM Source Off Temp = 163 deg. 43 days, 0 : 0 : 0 12/08/07 01:22.11 AM Source On Temp = 152 deg. ( 8 ) 12/08/07 01:22.30 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 2606 of 3600 = 72 % Source Ratio = 1637 of 3600 = 45 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 72 % Temp Change Factor = - 8 Deg Change Increment = 2 Old Temp Set Point = 163 deg. New Temp Set Point = 161 deg. 12/08/07 01:30.44 AM Source Off Temp = 161 deg. 12/08/07 01:32.20 AM Thermostat On Temp = 162 deg. 12/08/07 01:39.51 AM Source On Temp = 150 deg. 12/08/07 01:54.54 AM Source Off Temp = 161 deg. 12/08/07 02:08.36 AM Source On Temp = 150 deg. ( 9 ) 12/08/07 02:21.41 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 3003 of 3600 = 83 % Source Ratio = 2215 of 3600 = 61 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 83 % Temp Change Factor = 3 Deg Change Increment = 2 Old Temp Set Point = 161 deg. New Temp Set Point = 162 deg. 12/08/07 02:24.59 AM Source Off Temp = 162 deg. 12/08/07 02:37.17 AM Source On Temp = 151 deg. 12/08/07 02:52.30 AM Source Off Temp = 162 deg. 12/08/07 03:05.49 AM Source On Temp = 151 deg. 12/08/07 03:18.22 AM Source Off Temp = 162 deg. ( 10 ) 12/08/07 03:20.53 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 3600 of 3600 = 100 % Source Ratio = 1891 of 3600 = 52 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 100 % Temp Change Factor = 20 Deg Change Increment = 2 Old Temp Set Point = 162 deg. New Temp Set Point = 166 deg. 12/08/07 03:26.43 AM Source On Temp = 155 deg. 12/08/07 03:41.03 AM Thermostat Off Temp = 165 deg. 12/08/07 03:41.35 AM Source Off Temp = 166 deg. 12/08/07 03:56.48 AM Source On Temp = 155 deg. 12/08/07 04:06.14 AM Source Off Temp = 166 deg. 12/08/07 04:07.00 AM Thermostat On Temp = 168 deg. 12/08/07 04:14.50 AM Source On Temp = 155 deg. ( 11 ) 12/08/07 04:20.10 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 2026 of 3600 = 56 % Source Ratio = 1801 of 3600 = 50 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 56 % Temp Change Factor = - 24 Deg Change Increment = 2 Old Temp Set Point = 166 deg. New Temp Set Point = 161 deg. 12/08/07 04:22.28 AM Source Off Temp = 161 deg. 12/08/07 04:36.15 AM Source On Temp = 150 deg. 12/08/07 04:47.04 AM Source Off Temp = 161 deg. 12/08/07 05:00.39 AM Source On Temp = 150 deg. 12/08/07 05:10.53 AM Source Off Temp = 161 deg. ( 12 ) 12/08/07 05:19.28 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 3600 of 3600 = 100 % Source Ratio = 1419 of 3600 = 39 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 100 % Temp Change Factor = 20 Deg Change Increment = 2 Old Temp Set Point = 161 deg. New Temp Set Point = 165 deg. 12/08/07 05:20.07 AM Source On Temp = 154 deg. 12/08/07 05:32.28 AM Source Off Temp = 165 deg. 12/08/07 05:45.55 AM Source On Temp = 154 deg. 12/08/07 05:58.12 AM Source Off Temp = 165 deg. 12/08/07 06:10.46 AM Source On Temp = 154 deg. 12/08/07 06:11.06 AM Thermostat Off Temp = 154 deg. ( 13 ) 12/08/07 06:18.44 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 3135 of 3600 = 87 % Source Ratio = 1983 of 3600 = 55 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 87 % Temp Change Factor = 7 Deg Change Increment = 2 Old Temp Set Point = 165 deg. New Temp Set Point = 166 deg. 12/08/07 06:19.42 AM Source Off Temp = 166 deg. 12/08/07 06:31.43 AM Source On Temp = 155 deg. 12/08/07 06:38.00 AM Thermostat On Temp = 158 deg. 12/08/07 06:45.47 AM Source Off Temp = 166 deg. 12/08/07 07:00.29 AM Source On Temp = 155 deg. ( 14 ) 12/08/07 07:17.59 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 2432 of 3600 = 67 % Source Ratio = 1981 of 3600 = 55 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 67 % Temp Change Factor = - 13 Deg Change Increment = 2 Old Temp Set Point = 166 deg. New Temp Set Point = 163 deg. 12/08/07 07:27.19 AM Source Off Temp = 163 deg. 12/08/07 07:41.13 AM Source On Temp = 152 deg. 12/08/07 07:52.55 AM Source Off Temp = 163 deg. 12/08/07 07:59.20 AM Thermostat Off Temp = 161 deg. 12/08/07 08:12.21 AM Source On Temp = 152 deg. ( 15 ) 12/08/07 08:17.15 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 2513 of 3600 = 69 % Source Ratio = 1579 of 3600 = 43 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 69 % Temp Change Factor = - 11 Deg Change Increment = 2 Old Temp Set Point = 163 deg. New Temp Set Point = 161 deg. 12/08/07 08:20.23 AM Source Off Temp = 161 deg. 12/08/07 08:29.34 AM Thermostat On Temp = 158 deg. 12/08/07 08:33.35 AM Source On Temp = 150 deg. 12/08/07 08:48.02 AM Source Off Temp = 161 deg. 12/08/07 08:59.28 AM Source On Temp = 150 deg. ( 16 ) 12/08/07 09:16.27 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 2853 of 3600 = 79 % Source Ratio = 2105 of 3600 = 58 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 79 % Temp Change Factor = - 1 Deg Change Increment = 2 Old Temp Set Point = 161 deg. New Temp Set Point = 161 deg. 12/08/07 09:19.05 AM Source Off Temp = 161 deg. 12/08/07 09:30.17 AM Source On Temp = 150 deg. 12/08/07 09:30.45 AM Thermostat Off Temp = 149 deg. 12/08/07 09:43.00 AM Source Off Temp = 161 deg. 12/08/07 09:58.55 AM Source On Temp = 150 deg. 12/08/07 10:06.02 AM Thermostat On Temp = 157 deg. 12/08/07 10:07.49 AM Source Off Temp = 161 deg. ( 17 ) 12/08/07 10:15.43 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 1458 of 3600 = 40 % Source Ratio = 1476 of 3600 = 41 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 40 % Temp Change Factor = - 40 Deg Change Increment = 2 Old Temp Set Point = 161 deg. New Temp Set Point = 153 deg. 12/08/07 10:27.49 AM Source On Temp = 142 deg. 12/08/07 10:52.49 AM Source Off Temp = 153 deg. menu 1 ) Analysis Interval = 60 min. 2 ) System Startup Delay = 1 min. 3 ) Demand Ratio Ideal = 80 % 4 ) Actual Demand Ratio Min = 10 % 5 ) Startup Temperature = 155 deg. 6 ) Deg Change Increment = 2 deg. 7 ) Range Differential = 10 deg. 8 ) High Temp Absolute = 180 deg. 9 ) High Temp Safety = 250 deg. 10 ) Low Temp Absolute = 135 deg. 11 ) Low Temp Safety = 50 deg. 12 ) Temperature Averaging = 5 sec. 13 ) Thermostat Polarity = 0 deg. 14 ) HotWaterLowTemp = 0 deg. >12/08/07 11:03.26 AM Thermostat Off Temp = 146 deg. 12/08/07 11:09.21 AM Source On Temp = 142 deg. ( 18 ) 12/08/07 11:14.54 AM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 2903 of 3600 = 80 % Source Ratio = 1863 of 3600 = 51 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 80 % Temp Change Factor = 0 Deg Change Increment = 2 Old Temp Set Point = 153 deg. New Temp Set Point = 153 deg. 12/08/07 11:16.53 AM Source Off Temp = 153 deg. 12/08/07 11:37.27 AM Source On Temp = 142 deg. 12/08/07 11:47.30 AM Thermostat On Temp = 150 deg. 12/08/07 11:48.15 AM Source Off Temp = 153 deg. 12/08/07 12:02.14 PM Source On Temp = 142 deg. 12/08/07 12:12.00 PM Source Off Temp = 153 deg. ( 19 ) 12/08/07 12:14.01 PM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 1619 of 3600 = 44 % Source Ratio = 1377 of 3600 = 38 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 44 % Temp Change Factor = - 36 Deg Change Increment = 2 Old Temp Set Point = 153 deg. New Temp Set Point = 146 deg. 12/08/07 12:23.43 PM Thermostat Off Temp = 148 deg. temp Temp = 136 deg. >12/08/07 12:51.09 PM Thermostat On Temp = 136 deg. 12/08/07 12:51.09 PM Thermostat Off Temp = 136 deg. 12/08/07 12:51.55 PM Source On Temp = 135 deg. 12/08/07 01:00.25 PM Source Off Temp = 146 deg. 12/08/07 01:07.02 PM Thermostat On Temp = 151 deg. ( 20 ) 12/08/07 01:13.12 PM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 968 of 3600 = 26 % Source Ratio = 519 of 3600 = 14 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 26 % Temp Change Factor = - 54 Deg Change Increment = 2 Old Temp Set Point = 146 deg. New Temp Set Point = 135 deg. 12/08/07 01:18.29 PM Source On Temp = 134 deg. 12/08/07 01:29.52 PM Source Off Temp = 145 deg. 12/08/07 01:48.01 PM Thermostat Off Temp = 138 deg. 12/08/07 01:52.25 PM Source On Temp = 134 deg. 12/08/07 02:02.03 PM Source Off Temp = 145 deg. ( 21 ) 12/08/07 02:12.18 PM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 2121 of 3600 = 58 % Source Ratio = 1283 of 3600 = 35 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 58 % Temp Change Factor = - 22 Deg Change Increment = 2 Old Temp Set Point = 145 deg. New Temp Set Point = 141 deg. 12/08/07 02:30.49 PM Thermostat On Temp = 140 deg. menu 1 ) Analysis Interval = 60 min. 2 ) System Startup Delay = 1 min. 3 ) Demand Ratio Ideal = 80 % 4 ) Actual Demand Ratio Min = 10 % 5 ) Startup Temperature = 155 deg. 6 ) Deg Change Increment = 2 deg. 7 ) Range Differential = 10 deg. 8 ) High Temp Absolute = 180 deg. 9 ) High Temp Safety = 250 deg. 10 ) Low Temp Absolute = 135 deg. 11 ) Low Temp Safety = 50 deg. 12 ) Temperature Averaging = 5 sec. 13 ) Thermostat Polarity = 0 deg. 14 ) HotWaterLowTemp = 0 deg. >edit 10 The current Low Temp Absolute = 135 deg. Enter the new Low Temp Absolute : > 140 > OK. Setting Low Temp Absolute = 140 deg. >12/08/07 02:31.53 PM Source On Temp = 139 deg. Saving Settings...Done. menu 1 ) Analysis Interval = 60 min. 2 ) System Startup Delay = 1 min. 3 ) Demand Ratio Ideal = 80 % 4 ) Actual Demand Ratio Min = 10 % 5 ) Startup Temperature = 155 deg. 6 ) Deg Change Increment = 2 deg. 7 ) Range Differential = 10 deg. 8 ) High Temp Absolute = 180 deg. 9 ) High Temp Safety = 250 deg. 10 ) Low Temp Absolute = 140 deg. 11 ) Low Temp Safety = 50 deg. 12 ) Temperature Averaging = 5 sec. 13 ) Thermostat Polarity = 0 deg. 14 ) HotWaterLowTemp = 0 deg. >rtm 0 days remaining. >12/08/07 02:44.27 PM Source Off Temp = 150 deg. 12/08/07 03:06.46 PM Source On Temp = 139 deg. ( 22 ) 12/08/07 03:11.27 PM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 2477 of 3600 = 68 % Source Ratio = 1056 of 3600 = 29 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 68 % Temp Change Factor = - 12 Deg Change Increment = 2 Old Temp Set Point = 150 deg. New Temp Set Point = 148 deg. 12/08/07 03:16.48 PM Source Off Temp = 150 deg. 12/08/07 03:29.15 PM Source On Temp = 139 deg. >pressure 10 lbs >12/08/07 03:30.36 PM Thermostat Off Temp = 138 deg. 12/08/07 03:38.34 PM Source Off Temp = 150 deg. 12/08/07 03:52.45 PM Source On Temp = 139 deg. 12/08/07 04:02.36 PM Source Off Temp = 150 deg. 12/08/07 04:08.31 PM Thermostat On Temp = 154 deg. ( 23 ) 12/08/07 04:10.33 PM Cycle Time Elapsed = 60 min. 0 sec. Th On Ratio = 1291 of 3600 = 35 % Source Ratio = 1496 of 3600 = 41 % Ideal Demand Ratio = 80 % Actual Demand Ratio = 35 % Temp Change Factor = - 45 Deg Change Increment = 2 Old Temp Set Point = 150 deg. New Temp Set Point = 141 deg. 12/08/07 04:11.35 PM Source On Temp = 139 deg. 12/08/07 04:22.03 PM Source Off Temp = 150 deg. 12/08/07 04:33.43 PM Source On Temp = 139 deg. 12/08/07 04:39.25 PM Thermostat Off Temp = 139 deg. save Saving Settings...Done. >12/08/07 04:40.25 PM Thermostat On Temp = 141 deg. 12/08/07 04:40.25 PM Thermostat Off Temp = 141 deg.